Komatsu pc430-8 excavator has not been repaired before Recently, the gear pump of excavator vibrates severely.
Failure cause analysis:
1. Air intake at the end face seal The fitting between the end cover hole of the pump and the outer diameter of the gland is not good
2. Check the gear profile accuracy, the perpendicularity of the gear inner hole and the end face, the parallelism of the axis of the two holes on the cover plate, the parallelism of the two end faces of the pump body, the high tooth surface roughness, whether the length of the common normal is out of tolerance, whether the backlash is too small, etc
3. Whether the end clearance is too small The internal parts of the pump are worn and damaged
Troubleshooting:
1. Check whether the end face seal where the pump body is in direct contact with the end covers on both sides has air intake. If so, deal with the contact surface Check whether there is a poor fit between the gland of the pump and the hole of the outer diameter end cap, resulting in loose sealing, thus allowing air to enter. If there is, seal and reinforce it.
2. If any fault is found in this item, it is recommended to replace or grind the gear Check whether the end clearance is too small, making it difficult for the gear to rotate.
3. Check whether the parts inside the pump are damaged and worn, and if so, it is recommended to replace them; Fault found As the internal parts of the pump are found to be damaged, it is recommended to disassemble and repair the gear pump and repair or replace the bearing.