Fault performance:

When a Kato hd2048 excavator is walking and operating accessories at the same time, "the machine can't walk in a straight line". What are the common reasons for the "excavator can't walk in a straight line"? How to solve the problem? Here is master Li, a professional technician of meiruite excavator repair factory, to answer the problem in detail

The common causes of "Kato excavator" unable to travel in a straight line "are as follows:

1、 Excavator linear travel valve failure: 1 The spool valve is stuck 2 The spring is damaged or deformed 3 Spool valve orifice blocked

2、 Solve the fault of left and right neutral stop valve 1 Spool valve stuck 2 The spring is damaged or deformed 3 Excessive clearance between left or right bushing and slide valve 4 Spool valve orifice blocked

3、 Excavator main overflow valve fault 1 There are foreign matters between the main cone valve and the seat 2 There is foreign matter between the cone valve and the seat 3 Main cone valve stuck 4 The spring is damaged or deformed 5 Main cone valve throttle blocked 6 Loose adjusting screw

The above found out the common causes of "Kato excavator can not walk in a straight line." how to solve the troubleshooting measures of "excavator can not walk in a straight line"?

The troubleshooting measures for "Kato excavator" unable to walk in a straight line "are as follows:

1、 Measuring pilot pressure: 1 Grind the clamped part with an oilstone, etc. 2 Replace spring 3 Remove foreign matters

Two "measure the pilot pressure: 1. grind the clamped part with an oilstone 2. replace the spring 3. replace the slide valve 4) remove foreign matters

3、 Replace the main overflow valve: 1 Remove and clean "if severely damaged" and replace the assembly completely Grind the clamping part 3 with an oilstone Replace spring 4 Remove foreign matters 5 Readjust or tighten the split nut according to the specified torque.