The elevator is a multi-functional lifting mechanical equipment, usually used for rescue and decoration. With the constant attention to safety issues, how to safely and correctly operate construction elevators is always a topic for elevator construction personnel.
1. The construction elevator driver must be trained in safety technology, be in good health, and obtain a special operation certificate before operating independently.
2. The construction elevator driver must be in good health, including good eyesight in both eyes, no color blindness, no hearing impairment in both ears, no hypertension, heart disease, epilepsy, dizziness and sudden illness, no diseases and physical defects that impede operation .
3. The driver of the construction elevator must be familiar with the performance and structure of the elevator being operated, and operate in accordance with the relevant regulations of the elevator, and illegal operations are strictly prohibited. Drivers should be familiar with elevator maintenance and repair knowledge, and perform routine maintenance on elevators as required.
4. No trench shall be excavated within 5 meters of the elevator base on site; within 2.5 meters of the elevator bottom cage, a solid protective shed shall be built.
5. Conscientiously complete the handover procedures, check the filling status and recorded items of the elevator resume and handover records, and fill in the operation records carefully.
6. Check the technical condition of the external elevator before work, check the sturdiness of the bolts at the location, horizontal and vertical supports and platforms and protective doors, wire ropes and pulleys, transmission systems, electrical lines, meters, accessories and control buttons, etc., if they are found to be abnormal It should be eliminated in time, and the driver should report in time if it cannot be eliminated.
7. Check the conditions of the stoppers and safety devices at various parts. After checking the correctness, first raise the elevator cage of the construction elevator to 1 meter from the ground to stop and check whether the brake meets the requirements. Then continue to go up and test the discharge platform and protection The operation of the door, upper limit and front and rear door limit can be operated only after confirming that it is normal.
8. Before the operation of the construction elevator, the whistle must be sounded for warning; before the elevator is cut off the main power switch, the driver is not allowed to leave the operation position. After the operation, lower the elevator to the ground floor, pull each control switch to zero position, cut off the power, and lock the distribution box and the elevator door.
9. Overloading and overloading are strictly prohibited. Carrying goods should be evenly distributed to prevent unbalanced loading. The material should not exceed the ladder cage. It is forbidden for people to get on and off without reaching the prescribed parking position.
10. When running to the upper and lower ends, it is not allowed to stop at the limit (except for inspection); maintenance operations are strictly prohibited during operation. When a ladder cage is used for maintenance and maintenance outside the cage, the other ladder cage must not be operated .
11. In case of severe weather, such as thunderstorms, strong winds above level 6, heavy fog, and icing on the guide rails, the operation should be stopped; the operation should be stopped when the lights are unclear and the signal is unclear; the elevator machinery should be stopped before it is completely eliminated; If the wire wear exceeds the specified limit, the operation shall be stopped.
12. After the storm, safety inspection shall be carried out on the base, power supply, grounding, bridge crossing and temporary support of the construction elevator.